Skip to content

Recirculating chillers: KTR, KTD, KTC from ATC – cooling capacity: 480 W

These are inexpensive, robust, small active air/water flow-through coolers for low cooling capacities

ATC is the UK’s leading manufacturer of recirculating chillers and temperature control products. From standard products to fully customized systems, ATC can offer you the best cooling solution and temperature control for your problems.

What makes the device special:

  • small
  • simpel & robust
  • favorable

Use for cooling / temperature control of:

  • lab equipment
  • research and development activities
  • manufacturing processes with low waste heat output

Relevant performance specifications

KTRKTDKTC
Cooling capacity1480 Watt480 Watt480 Watt
Temperature range
(standard)
+ 4 °C to + 35°C+ 4 °C to + 35°C+ 4 °C to + 35°C
Temperature range
(optional)
n.a.n.a.-10 °C bis +65 °C
Temperatur
stability at constant load
+/- 0.2 °C+/- 0.2 °C+/- 0.1 °C
Principlecompression chiller

active air / water chiller
compression chiller

active air / water chiller
compression chiller

active air / water chiller
pump options and flow ratesP2 – 2 l/min
P3 – 3 l/min
P2 – 2 l/min
P3 – 3 l/min
P2 – 2 l/min
P3 – 3 l/min
System volume1.5 l1.5 l1.5 l
CompatibilityHexid, propylene-glycol, destilled waterHexid, propylene-glycol, destilled waterHexid, propylene-glycol, destilled water
Operating pressure range1.4 – 10 bar1.4 – 10 bar1.4 – 10 bar

1 Performance at 20°C ambient temperature at the chiller and 20°C setpoint for application to be cooled

Other relevant specifications

KTRKTDKTC
Weight30 kg30 kg30 kg
Size (L x W x H)330 x 315x 515
mm
330 x 315x 515
mm
330 x 315x 515
mm
Noise level55 dB (A) 1m55 dB (A) 1m55 dB (A) 1m
F-gas amount2 /
type, GWP1 and
CO2 equivalent
0.42 kg R134a
(GWP 1430)
0.6 t CO2
0.42 kg R134a
(GWP 1430)
0.6 t CO22
0.42 kg R134a
(GWP 1430)
0.6 t CO2
Operating voltage and
maximum power
requirement / for 50 Hz
230 V – 2.5 A230 V – 2.5 A230 V – 2.5 A
Environmental
temperature
+ 4 °C bis + 40 °C+ 4 °C bis + 40 °C+ 4 °C bis + 40 °C
Min. inside diameter
of pipeline
12 mm12 mm12 mm

1GWP: Global warming potential – the global warming potential that this refrigerant has compared to CO2 over a period of 100 years

Manuals for download:

Brochures and other information for download:

Inquiries regarding offer and advice please contact office@labsupport.at